Commercial & institutional buildings
Outdoor air rates, exhaust and air distribution for offices, retail, schools, places of worship and recreation venues, with energy or heat recovery where it pays back.
OBC Part 6 · ASHRAE 62.1Ventilation designed to the regulation that governs your building—from apartments and offices to commercial kitchens, parking garages, clinics and industrial processes.
Ventilation rules differ by occupancy, process and contaminant. EEB identifies which code, standard or workplace regulation applies before sizing the system.
Outdoor air rates, exhaust and air distribution for offices, retail, schools, places of worship and recreation venues, with energy or heat recovery where it pays back.
OBC Part 6 · ASHRAE 62.1Mechanical ventilation and heat recovery ventilators for houses, apartments and multi-unit residential buildings.
OBC Section 9.32 (Part 9) · ASHRAE 62.1 / 62.2 for Part 3 residentialHood exhaust, grease duct routing, make-up air and building pressure balance for restaurants, including solid-fuel cooking.
NFPA 96 · OBCExhaust and supply systems controlled by carbon monoxide and nitrogen dioxide gas detection for storage garages, repair bays and heated garages.
OBC · CO/NO₂ detection-controlled ventilationLocal exhaust ventilation, source capture hoods, ductwork and dust collector design, including combustible dust applications.
O. Reg. 851 (Industrial Establishments) · Reg. 833 exposure limits · NFPA 660Ventilation, pressure relationships and exhaust for dental offices, physiotherapy clinics and care facilities.
CSA Z317.2 where applicable · OBCFor existing buildings and workplaces, EEB reviews the installed systems, operating data and contaminant sources, calculates the required ventilation and reports where the facility falls short—with practical upgrade options.
Ventilation interacts with heating, cooling, fire protection, electrical and structure. Because EEB designs those disciplines in-house, fans, make-up air units, duct penetrations, roof supports and gas detection wiring are coordinated on one drawing set.
Codes & standards: Ontario Building Code (Part 6 and Section 9.32), ASHRAE 62.1 and 62.2, NFPA 96, NFPA 660 (combustible dusts, formerly NFPA 652/654), CSA Z317.2, O. Reg. 851 and Reg. 833 under the Occupational Health and Safety Act. Out-of-province projects follow the applicable provincial regulations. Drawings and calculations are sealed by a licensed Ontario P.Eng.

Send your building location, available drawings, required services and target schedule. EEB will discuss the technical requirements and prepare an appropriate proposal.
Request an estimate →It depends on the occupancy and what is being exhausted. Commercial and institutional buildings follow OBC Part 6 and ASHRAE 62.1; houses follow OBC Section 9.32; commercial kitchens follow NFPA 96; workplaces with process contaminants are also governed by Ontario's occupational health and safety regulations. EEB confirms the governing requirements first.
In most cases, yes. Air removed by the hood has to be replaced, or the building goes negative—causing door, draft and appliance problems. EEB sizes the exhaust and make-up air together to NFPA 96 and the OBC.
Yes, within a defined scope. EEB designs source capture, duct velocities and collector arrangements using the process information and dust hazard analysis, coordinated with the NFPA 660 requirements that apply to the facility.
Yes. EEB reviews the installed systems and process information, calculates required ventilation and reports any compliance gaps with practical upgrade options.
Yes. EEB designs garage exhaust and supply systems controlled by carbon monoxide and nitrogen dioxide gas detection, coordinated with the electrical design.
The building use, floor area and ceiling heights, the processes or contaminants involved (safety data sheets for industrial work), existing equipment data, and any inspection or order you need to respond to.